<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-12 22-45-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 48 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.4 kHz 68 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 64 kHz 19076 6,5265
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,25 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 22:45, 12.12.2025
RT
"Rony Rex (u) "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 64 kHz MIN: 12 kHz % above 76 kHz: 6,5265 Acquired: 2025/12/12 22.44.41 Total samples: 19076 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,7 dBr MIN: 4,3 dBr AVE: 5,25 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/12/12 22.44.41) 22.30 22.32 22.34 22.36 22.38 22.40 22.42 22.44 0 2 4 6 Pm [dBr]